On 07/01/2016 04:08 AM, William Brown wrote:
if we start the total update here, the supplier will send its RUV in the start repl request, it will be set as RUV in the consumer after total init is complete.On Thu, 2016-06-30 at 14:53 -0700, Noriko Hosoi wrote:On 06/30/2016 12:45 AM, Ludwig Krispenz wrote:Hi William, the reason that after a total init the consumer does not have the latest state of the supplier RUV and is receiving updates based on the RUV at start of the total init is independent of the modrdn problem. When a supplier is performing a total init it is still accepting changes, the total init can take a while and there are scenarios where an entry which is already sent is updated before total init finishes. We cannot loose these changes.OK... Then, RUV needs to be created at the time when the supplier starts online init? The test case would be something like this? 1. run online init on the supplier. 2. do some operation like move entries against the supplier while the online init is still running on the consumer. 3. do some operation which depends upon the previous operation done in the step 2. 4. check the consumer is healthy or not. Isn't it a timestamp issue from which operation should be replayed after the total update? Regardless of the way how to fix 48755, unless the step 2 operation(s) are replayed after the online init is done, the consumer could get broken/inconsistent?It's not the "post init" operations I'm worried about. It's that operations that were part of the init to the consumer are replayed from the changelog. Operations that occurred after the init starts, definitely still need to be replayed, and this makes sense. Lets say we have: 1 - insert A 2 - insert ou=B 3 - modrdn A under ou=B 4 - insert C xxxxxx <<-- We start to transmit the data here.
it skips to send the ruv entry
so mods 1-4 will not be replayed
it is5 - modrdn C Once the online init is complete, the master replays the log from event 1 -> 5 to the consumer, even though it should now be up to date at position 4.
yes, and I think that is what it is doing nowPreviously we could not guarantee this because in the scenario above, A would have sorted before ou=B, by would not be able to be applied because the consumer hadn't seen B yet. So after the init, the consumer would have B and C, but not A, so we had to replay 1 -> 4 to fix this up. So I am suggesting that when we begin the online init we set the RUV of the consumer to match the CSN of the master at the moment we begin the transmission of data, so that we only need to replay event 5+, rather than 1->5+ Does that make sense?
-- 389-devel mailing list 389-devel@lists.fedoraproject.org https://lists.fedoraproject.org/admin/lists/389-devel@lists.fedoraproject.org
-- Red Hat GmbH, http://www.de.redhat.com/, Registered seat: Grasbrunn, Commercial register: Amtsgericht Muenchen, HRB 153243, Managing Directors: Charles Cachera, Michael Cunningham, Michael O'Neill, Eric Shander
No comments:
Post a Comment